Alarm code: 2005
Supply air temperature min alarm
Description
The temperature level surrounding the temperature sensor is unnaturally low.
Instructions
Check for possible reason why supply air temperature is extremely low.
At low outside temperatures together with functions that increase the supply air/imbalance (e.g. cooker hood) there may be a need for post-heating to achieve an acceptable supply air temperature.
Clogged exhaust air filter or low exhaust air flow/high supply air flow increases the risk of the alarm occurring.
- Consider activating the post-heat element using the procedure described for the Flexit GO app or control panel, depending on which method you are using.
- In case of recurring problem behaviour, the commissioned air flows shall be reviewed to ensure correct function.
- If no action solves your problem, contact your service partner.