Alarm code: 2019
Heat pump, B31 - high return temperature
Description
The heat pump have tried to restart several times but is shut down due to high return temperature. Low energy consumtion on the seconadary side is making the heat pump shut down due to high return temperature.
Instructions
- Check the underfloor heating pressure. Min. 1 bar.
- Could be air on the underfloor heating side.
-Clogged water filter underfloor heating.
-Actuators do not open so that there is little consumption of underfloor heating. - Try to reset the alarm following the procedure described for the Flexit GO app or control panel, dependant on which device you are using.
- Adjust the lower boundry for the mid range area to a lower value in order to make the heat pump work in a better load area.
- In case this action doesn’t solve your problem, please contact your service partner.