FAQ
What is the installed power of EcoNordic?
EcoNordic has a maximum installed power of 6.4 kW. The system is BBR-compliant and can be configured with a lower power output at start-up if required by the building. This flexibility makes EcoNordic suitable for both new and existing homes with different energy demands.
What does Flexit’s design and engineering service cost?
The cost of Flexit’s design and engineering services depends on the type of project, its size and the required deliverables. For updated and detailed pricing information, we refer to the current price list. If you are unsure which design service is relevant for your project, we recommend contacting Flexit or your local Flexit representative for guidance.
Who can I contact for quotes/purchase and installation of balanced ventilation?
We recommend that you contact a Flexit partner. Find your nearest Flexit Partner here >> (check for Flexit partner in the filtering)
Which kitchen hoods can be used in shared ventilation systems?
For shared systems, kitchen hoods that are specifically designed and approved for use in such systems must be used. Flexit offers dedicated kitchen hoods for shared ventilation systems that are adapted for correct operation and interaction with the system. An overview of which models can be used is available on Flexit’s website under kitchen hoods for shared systems.
What is the operating time of a central vacuum cleaner?
The central vacuum cleaner has an operating time of 20 hours before it needs to be reset. After every 20 hours of operation, the unit must be reset by pressing and holding the on/off button on the main unit. This is a normal part of operation and ensures proper function over time.
What information do you need when I order spare parts for a airhandling unit?
To supply the correct spare parts, we need the serial number of your airhandling unit. The serial number is required because there may be several different spare part variants within the same unit type. With the correct serial number, we can ensure that the parts fit and function as intended.
What IP rating do Flexit products have?
The IP rating varies from product to product within the Flexit range. The applicable IP rating for your product can be found in the user manual for the specific product. The manual provides correct and up-to-date information about the enclosure class and intended area of use.
What corrosion class do Flexit combination boxes have?
Flexit combination boxes have a corrosion class corresponding to C4. This means they are suitable for use in environments with moderate to high corrosive exposure and provide good protection against moisture and external stress over time.
Which replacement motor can I use for a ULV central exhaust unit?
The correct replacement motor for a ULV central exhaust unit depends on the unit’s design and when it was manufactured.If the unit has an oval mounting plate and was produced after April 2002, replacement motor with article number 98320 should be used.If the unit has a round mounting plate with a 3-pin connector and was produced from 1992 to April 2002, replacement motor with article number 98319 should be used.If the unit has a round mounting plate with a 5-pin connector and was produced between 1989 and January 1992, replacement motor with article number 98301 should be used.If the unit has a round mounting plate with a standard connector and was produced before January 1989, replacement motor with article number 98300 should be used.
Which replacement motor can I use for a USV central exhaust unit?
The correct replacement motor for a USV central exhaust unit depends on the type of mounting plate the unit has.If the unit has an oval mounting plate and was produced after April 2002, a replacement motor with article number 98320 should be used.If the unit has a round mounting plate and was produced before April 2002, a replacement motor with article number 98319 should be used.